MF Series 1-10KVA Online UPS Single Phase

Online UPS manufactured and supplied by SM-VOLTSMART is the most preferred online UPS.

Features
  • True Online, Double Conversion, PWM Technology
  • CVCF (Constant Voltage Constant Frequency)
  • LCD Display and Wide Input Voltage Range
  • High Input Power Factor >0.99
  • Static Bypass and Cold Start
  • Warranty - 1 Year
Category: Online UPS
Product Description

SM-VOLTSMART, manufactures the Online UPS with PWM technology. We have a highly qualified team of professionals for ensuring that the UPS is manufactured as per with the standard norms and according to the specific requirements of the customers. The Online UPS have been widely demanded in PC, Servers, Networking Equipments, Security Systems, Medical Equipments etc.

 

Special Features
  • True Online, Double Conversion, PWM Technology
  • Fully Digitized Microprocessor Control, High Frequency, Pure Sine Wave Output
  • CVCF (Constant Voltage Constant Frequency)
  • LCD Display and Wide Input Voltage Range
  • High Input Power Factor >0.99
  • Static Bypass and Cold Start
  • IGBT Based - Inverter & Rectifier
  • Isolation Transformer Compatible
  • Advanced Battery Management
  • Automatic Battery Charge in UPS Off Mode
  • EMI/RFI and Noise Filter
  • Generator and Solar Compatible
  • High Reliability Digital Control
  • Auto-start Function
  • ECO Mode

 

Application

PC, Servers, Networking Equipments, Security Systems, Medical Equipments etc.

Technical Specifications
Capacity 1 KVA, 2 KVA, 3 KVA, 5 KVA, 6 KVA, 10 KVA
Input Voltage Range 220V/230V/240V AC (1Ph+N+PE, 3 Wire)
Operating Voltage Range 110V~300V AC Load Dependent
Operating Frequency Range 50 / 60 Hz ± 10% (Auto Sensing)
Power Factor >0.99
Output Voltage/Power Factor 220V / 230V / 240V AC / ±1% / 0.8 Std., 0.9 Optional
Output Frequency Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode
Harmonic Distortion (THDv) <2% (Linear load), <5% (Non Liner Load)
Crest Factor 3:1
Efficiency Up to 94% Dual Conversion Mode, 99% ECO Mode
DC Voltage 36V, 48V, 72V, 96V, 72V, 96V, 192-220V Configurable
Charge Current 6.5 A Configurable
Typical Recharge Time 8 Hours (90% of full capacity)
LCD Indication Input Voltage/Frequency, Output Voltage/Frequency, Battery Voltage, Load Watt/VA and %, Inverter Temperature, Operation Mode such as “On Line”, “ON Batt” or On “Bypass”, Fault Codes, Battery & Load Bar graph
LED Indication Normal Operation, Bypass, Abnormal, Fault and Battery Mode
Alarms / Protection Batt. Low, DC High, Inverter Under/Over Voltage, UPS Over Load, Short Circuit, Fan Failure and UPS Fault
Overload Capability ≤ 125% for 10 min, >125-150% for 1 min, >150% for 200 ms
Transfer Time AC to Battery : 0ms, Inverter to Bypass : 4ms (Typical)
Temperature Operating: 0~45°C, Storage: -10ºC ~ 55ºC
Humidity / Altitude 0~95% RH Non-condersing / <1500 M
Noise Low Audible Noise Level
Quality ISO 9000, ISO 14001, OHSAS 18001, ISO 27001, BIS, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE
Standard RS-232
Optional SNMP / ModBus / Dry Contact / USB / RS-485
Monitoring Software NetAgent Utility v5.8 / UPSilon 2000
Whatsapp