MF Series 1-10KVA Online UPS Single Phase
Online UPS manufactured and supplied by SM-VOLTSMART is the most preferred online UPS.
Features
- True Online, Double Conversion, PWM Technology
- CVCF (Constant Voltage Constant Frequency)
- LCD Display and Wide Input Voltage Range
- High Input Power Factor >0.99
- Static Bypass and Cold Start
- Warranty - 1 Year
Category: Online UPS
Product Description
SM-VOLTSMART, manufactures the Online UPS with PWM technology. We have a highly qualified team of professionals for ensuring that the UPS is manufactured as per with the standard norms and according to the specific requirements of the customers. The Online UPS have been widely demanded in PC, Servers, Networking Equipments, Security Systems, Medical Equipments etc.
Special Features
- True Online, Double Conversion, PWM Technology
- Fully Digitized Microprocessor Control, High Frequency, Pure Sine Wave Output
- CVCF (Constant Voltage Constant Frequency)
- LCD Display and Wide Input Voltage Range
- High Input Power Factor >0.99
- Static Bypass and Cold Start
- IGBT Based - Inverter & Rectifier
- Isolation Transformer Compatible
- Advanced Battery Management
- Automatic Battery Charge in UPS Off Mode
- EMI/RFI and Noise Filter
- Generator and Solar Compatible
- High Reliability Digital Control
- Auto-start Function
- ECO Mode
Application
PC, Servers, Networking Equipments, Security Systems, Medical Equipments etc.
Technical Specifications
Capacity | 1 KVA, 2 KVA, 3 KVA, 5 KVA, 6 KVA, 10 KVA |
Input Voltage Range | 220V/230V/240V AC (1Ph+N+PE, 3 Wire) |
Operating Voltage Range | 110V~300V AC Load Dependent |
Operating Frequency Range | 50 / 60 Hz ± 10% (Auto Sensing) |
Power Factor | >0.99 |
Output Voltage/Power Factor | 220V / 230V / 240V AC / ±1% / 0.8 Std., 0.9 Optional |
Output Frequency | Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode |
Harmonic Distortion (THDv) | <2% (Linear load), <5% (Non Liner Load) |
Crest Factor | 3:1 |
Efficiency | Up to 94% Dual Conversion Mode, 99% ECO Mode |
DC Voltage | 36V, 48V, 72V, 96V, 72V, 96V, 192-220V Configurable |
Charge Current | 6.5 A Configurable |
Typical Recharge Time | 8 Hours (90% of full capacity) |
LCD Indication | Input Voltage/Frequency, Output Voltage/Frequency, Battery Voltage, Load Watt/VA and %, Inverter Temperature, Operation Mode such as “On Line”, “ON Batt” or On “Bypass”, Fault Codes, Battery & Load Bar graph |
LED Indication | Normal Operation, Bypass, Abnormal, Fault and Battery Mode |
Alarms / Protection | Batt. Low, DC High, Inverter Under/Over Voltage, UPS Over Load, Short Circuit, Fan Failure and UPS Fault |
Overload Capability | ≤ 125% for 10 min, >125-150% for 1 min, >150% for 200 ms |
Transfer Time | AC to Battery : 0ms, Inverter to Bypass : 4ms (Typical) |
Temperature | Operating: 0~45°C, Storage: -10ºC ~ 55ºC |
Humidity / Altitude | 0~95% RH Non-condersing / <1500 M |
Noise | Low Audible Noise Level |
Quality | ISO 9000, ISO 14001, OHSAS 18001, ISO 27001, BIS, RoHS |
Safety | IEC/EN62040-1 |
EMC / Performance | IEC/EN62040-2; IEC/EN62040-3, Complying to CE |
Standard | RS-232 |
Optional | SNMP / ModBus / Dry Contact / USB / RS-485 |
Monitoring Software | NetAgent Utility v5.8 / UPSilon 2000 |